Description
Double Pantile Vent by Klober is a superb vent that works with Marley Mendip, Redland Grovebury, Russell Pennine and Sandtoft Double Pantile profiles. It’s suited for roof pitches of 17.5° and weighs under a kilo.
Installing a Double Pantile Vent
To begin the installation, make sure to specify the position of the Double Pantile vent. It should be in line with the tile below. After you’ve positioned it, score a 120mm x 180mm wide rectangle and make a star cut from opposite corners. Moving on, fold the four tabs back and upwards and ensure the top tab is secured to the batten overhead. For the final step, fix the vent tile in position, assuring the fixing clip is located under the left-hand interlock of the roof tile